Skip to content

GGU-AXPILE: Further EAP examples

A variety of further pile designs can be found in the EAP. The EAP examples below can be found in the example files provided. Analysis was carried out using the lower and the upper table values.

EAP example Pile type Page in EAP
B3 Bored pile 274
B4 Pre-cast driven pile 277
B5 Fundex pile 281
B6 Pre-cast driven pile 284
B7 Franki pile (pressure-injected toe) 288

Example 7 demonstrates design of a Franki pile. The design of Franki piles is essentially different to that of normal driven piles. The die characteristic load F(G,k) for permanent and F(Q,k) for changeable loads must be specified. The subsequent analysis then provides the required pile toe volume and the norm-driving work component W (see also “Theoretical principles: Pile design to EAP” Section "Design of Franki piles").